Operating precautions for MechaTransR

1)Hysteresis

The displacement of MechaTransR to be generated by increasing voltage a little bit differs from decreasing voltage. The difference, namely hysteresis comes from the inherent characteristics of piezoelectric devices. If it is required to control the displacement more precisely, it is recommended to add a displacement sensor onto the system.
As an example, the hysteresis loop of MechaTransR MTA02S200F2 is shown in Fig. 8.

2)Continuous DC voltage under high humidity

When DC voltage is supplied to MechaTransR for a long time under over 60% humid environment, the piezoelectric device may result in
an electrical short circuit which is said migration phenomenon. It is recommended to operate MechaTransR under dry environment such
as clean room. But In case of an intermittent operation, possibility of the migration may be very small even though under high humid
environment.

3)Avoid excess tensile force against PZT
         and/or compression force to the arm

An excess outer force to the piezoelectric device and the arm portion must be avoided. Because the
piezoelectric device is weak against a tensile force due to not only being made from a ceramic material,
also an initial pre-tension force given to the piezoelectric device itself. If an outer force is given to the
piezoelectric device through the arm, the force should be amplified by the lever structure.

4)Do not superimpose DC voltage instantaneously

If DC voltage is directly supplied to MechaTransR by using a switch and unless any resister is added onto MechaTransR in series, the maximum displacement may be twice, compared to the displacement under static conditions, and then MechaTransR may be damaged. In that case, it is recommended to add a suitable resister onto MechaTransR, to increase DC voltage gradually, or to control the voltage less than 80V.

5)Ambient temperature

If ambient temperature is increased +1 [℃], the displacement at the mechanical output point of MechaTransR should be the almost same as -1 [V] supply and the displacement direction is opposite to Fig.3. If MechaTransR is used under a changeable ambient temperature and its displacement amount cannot be so small to the system. Please contact us for the solution.

6)Polarization

If the polarity of the power supply is opposite to normal, the displacement should have the minus(-) direction up to approximately 20V.
But when the power supply is more than 20V, the displacement direction changes to plus(+) because of polarization of the piezoelectric device. If an alternating voltage is supplied to MechaTransR for a long time, the piezoelectric device may be destroyed. The right polarity connection of the power supply should be required except for a special occasion. The red color lead wire is normally connected to the
plus(+) polarity.



(The dimensions of each part are as Table2.)